20 m Navigation Safety|Laser Scanning Radar|DADISICK
- モデル
- LDS2030B5-5S Series
プロパティ
- Sensing range:
- 0.1 m ~ 20 m
- Scanning frequency:
- 25 Hz
- Scanning angle range:
- 300°
- Angular resolution
- 0.5°
- Light source:
- Infrared laser (905 nm)
- Laser safety level:
- Class 1 (GB7247.1-2012, Eye-safe IEC)
評価
製品の説明
Laser Scanning Radar Basic Information
|
||
Product number
|
Two-dimensional tof obstacle avoidance laser radar |
|
Model
|
LDS2030B5-5S |
|
Output | I/O output & Ethernet output |
Features
|
||
Light source
|
Infrared laser (905 nm) |
|
Laser safety level | Class I (GB 7247.1-2012, Eye safe IEC) | |
Laser spotlight diameter | 8 mm | |
Laser spotlight scan angle | 12.5 mrad | |
Scanning angle range
|
300° |
|
Scanning frequency
|
25 Hz |
|
Scanning Angular Resolution
|
0.5° |
|
Sensing range | 0.1 m ~ 20 m | |
10% reflectivity range | 15 m | |
Self-learning function | Automatic environment scanning, generating area | |
Outdoor performance | Anti-dusty, Anti-sunlight | |
Rain, fog and smoke penetration | Supported |
Technical Performance | ||
Measurement error ● System error {typical} ● Statistcal error {1 σ} | 1 cm | |
Built-in application | ● Regional monitoring ● Monitoring mode: Point number monitoring / target width monitoring / contour monitoring ● Monitor signal level: Attention / warning / alarm ● Number of regional groups: 16 groups, support self-learning background exclusion ● Concurrent work area group number: 16 (max) ● Guide the network camera to monitor the target video positioning and tracking | |
Self-test equipment | ● Contents: Transparent cover dirt / block / high temperature / low temperature ● Output mode: indicator + TCP packets | |
Device Interface | ||
Ethernet | Rate: 10/100 Mbps Network protocol: TCP/IP Function: Device configuration / measurement data output / monitor signal output | |
I/O Input | Input port: 4 Type: Level input High level range: DC 10 V - 30 V Low level range: DC 0 V - 1.2 V Preset functions: Monitor area group selection (0 × 0 ~ 0 × F) Forced cancellation / forced activation of regional monitoring signal, effective level: high level Power saving and life extension control, effective level: high level | |
I/O Output | Input port: 4 Type: PNP / NPN switch output Maximum switch voltage: DC30V Power-on state: OFF Preset function:
Device ready / area monitoring signal output, effective state: configurable | |
Indicator light | Quantity: 2 Definition: HTR (Run status indication: detection signal / self-learning / ready to restart) ERR (Device alarm: Transparent cover dirt / block, high and low temperature) | |
Front panel button | Quantity: 1 Definition: Shielded monitor signal output / start background self-learning / restart device | |
Mechanical/electronic paramete
|
||
Operating voltage
|
DC 10 V – 30 V |
|
Power dissipation
|
3.4 W (measuring), 7.6 W@DC 12 V / 6 W@DC 24 V (heating) |
|
Degree of protection (IP)
|
IP67 (GB 4208-2008) |
|
Insulation resistance | 1 MΩ (GB 16796 - 2009.5.4.4) | |
Electric strength | 0.5 KV (GB 16796 - 2009.5.4.3) | |
Dimension (L ╳ W ╳ H) | 80 ╳ 85 ╳ 102 (mm) | |
Interface cable lengt | 1 Meter | |
Weight | 0.6 kg |
DIMENSION

DOCUMENTS & DOWNLOADS
Catalogue
3D
Software Installation Package
Certificate